If your furnace keeps shutting off, it could be due to low airflow. There are several indirect issues that cause low airflow. Dirty Air Filters. If you don’t change your air filters often enough, the filters will become dirty and clogged, which means the heat exchanger retains heat and eventually causes it to overheat.
Why won’t the pilot stay lit on my wall heater?
The Pilot Won’t Stay Lit A pilot that won’t stay lit could be the result of a blockage in the pilot tube. Turn off the gas, clear the tube with compressed air, and relight the pilot. If that doesn’t work, you may need to call a repairman to come and install a new thermocouple.
How do you reset a gas wall heater?
Turn the power back on and then the main gas supply. Locate the reset button. It is labeled, sometimes in red. Press and hold the reset button for 30 seconds.
Why does my furnace keep shut off before reaching temperature?
A lack of airflow can cause your furnace to stop heating before reaching the set temperature. Ensure there is nothing impeding airflow around your furnace, within your furnace and through your ducts. Inside your furnace should be clean and free of debris, especially around the blower motor and the heat exchanger.
How much does it cost to replace a thermocouple?
It costs $150 to $250 to replace a thermocouple. It checks to make sure the pilot light is on. It will shut the gas off if it’s not.
Why does my pilot light keep going out after replacing thermocouple?
If your water heater pilot won’t stay lit even after replacing the thermocouple, you most likely have a faulty gas control valve. It is a sign that the valve is failing to open and allow gas to flow to the pilot. You could also be dealing with a tripped or faulty thermal switch.
Should I reset my heater?
If your furnace doesn’t have any air coming out at all and the pilot light is out, it’s worth it to try resetting the furnace. If this doesn’t work, there may be a problem with the thermostat setting, the power, or the gas line.
Where is the reset button on my heater?
Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.
How do you know a thermostat is bad?
7 Signs You Need to Replace Your Thermostat Your HVAC Keeps Turning On or Off. Faulty Thermostat Readings. Suspiciously High Energy Bills. Constant Temperature Shifts. Thermostat Is Too Old. Thermostat Fails to Respond to Changed Settings. Your HVAC System Short Cycles.
How do you fix a short cycle on a furnace?
The easiest way to fix a furnace that is short cycling is to remove the flame sensor to clean it. Use a sponge or brush to remove the dirt from the sensor. After the part is clean, follow the manufacturer’s instructions to insert the flame sensor into the furnace.
Why does my furnace turn on and off every few minutes?
When a furnace starts and shuts off, it could be a sign that you have low airflow. The heat exchanger in the furnace will often overheat if there isn’t enough airflow. The furnace won’t be able to pull fresh air into the blower if the air filters are clogged with dust, pet hair, and other debris.
Can I replace a thermocouple myself?
1 cause of pilot lights that won’t stay lit is a worn-out thermocouple. It’s easy to replace and a new one costs $5 to $10. Then detach the thermocouple from the burner and take it with you to the home center or hardware store to ensure you buy the right replacement.
How do I clean a thermocouple?
The best way to clean your thermocouple is to use either a piece of steel wool or the coarse side of a sponge to gently clean off any soot or other remnants. You can use a pencil eraser to clean between the threads of the screw that connects the thermocouple to the control valve of your system.
How long does a thermocouple last?
Thermocouples can last up to 10 years if properly installed and maintained, while furnaces can last 15-20 years, although either may wear out sooner in multifamily units.
What does it mean when your pilot light won’t stay lit?
If your pilot light won’t stay alight, it might be the thermocouple. Sometimes dust buildup collects on the thermocouple and blocks the sensor. Try cleaning the thermocouple and then relighting the pilot light. If it continues to go out, the thermocouple might need to be replaced.
How do you bypass a thermocouple?
To bypass the thermocouple: Move the tilts switch wire aside. Remove your thermocouple from the heater using an 8mm wrench. Pull the valve housing aside using your 13mm socket wrench. Remove the valve using your pliers. Put your thermocouple back into position.
Where is the reset button on gas furnace?
Locate the reset button on the furnace and press it to reset the furnace. It is usually located inside the blower compartment on the side of the blower motor. Be cautious as the housing may be hot. If the button is popped up, press it down.