Table of Contents
AFCI protection is currently required for all 15 and 20 amp branch circuits providing power to outlets* in residential family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, and similar rooms or areas.
Where are arc-fault breakers not required?
AFCI protection is not required for outlets located outside or in garages or bathroom areas. (B) All 15A or 20A, 120V branch circuits supplying outlets in dormitory unit bedrooms, living rooms, hallways, closets, bathrooms, or similar areas.
Where are arc-fault breakers required 2020?
In the 2020 edition of the NEC®, Section 210.12 requires that for dwelling units, all 120-volt, single-phase, 15- and 20-ampere branch circuits supplying outlets or devices installed in dwelling unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms,.
Where are arc-fault breakers required 2021?
16 states that AFCI protection is required for all 120-Volt, single phase, 15 and 20 amp branch circuits supplying outlets or devices installed in living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, and similar rooms or areas.
What circuits in a house need an arc-fault?
AFCIs are required on all 120-volt, single-phase circuits with 15 to 20 amps supplying receptacles in all dwelling rooms. If, for example, if you use your basement as a living room, playroom, or recreational room, then you will need to install an AFCI protection.
Are arc fault breakers required in garage?
The 2017 National Electrical Code (NEC) requires the protection of an arc fault circuit interrupter (AFCI) for 15 and 20 amp circuits in all newly built residential areas, but they are not needed in bathrooms, garages, or outdoor areas.
Do kitchens require AFCI?
The latest National Electrical Code requires both AFCI and GFCI protection only in kitchens and laundry rooms. And within those rooms, the Dual Function AFCI/GFCI Receptacle provides what is called “feed-through” protection, which means it provides protection for all wiring and extensions attached to the load side.
Where do I put my arc-fault breakers?
The AFCI shall be installed in a readily accessible location, and protect all 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets or devices installed in dwelling unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, Feb 5, 2019.
Do bathrooms need arc-fault breakers?
Note: Arc-Fault Circuit Interrupters (AFCIs) requirements have not expanded to the entire dwelling unit (to include bathrooms, basements and crawl spaces). Although some changes were made to the AFCI section in the code, they apply only to dorms and hotels/motels.
What circuits require an arc-fault Canada?
The Canadian Electrical Code requires homes to have arc-fault circuit protection installed for 125Vac, 15A and 20A circuits supplying receptacles throughout the home (with some exceptions).
Does refrigerator need AFCI?
Refrigerator Circuit A modern refrigerator requires a dedicated 20-amp circuit. This circuit usually does not require GFCI protection unless the outlet is within 6 feet of a sink or located in a garage or basement, but it generally does require AFCI protection.
Do lighting circuits require AFCI?
AFCI requirements. The NEC requires that virtually all branch circuits for lighting and receptacles in a home must have arc-fault circuit-interrupter (AFCI) protection.
Where are GFCI required?
The NEC mandates GFCI protection in many areas of the home: bathrooms, garages, outdoor receptacles, crawl spaces, basements, kitchens and anything within six feet of a sink or water source. While that may seem like a lot, the entirety of a home is not covered.
Does garbage disposal need AFCI?
The inclusion of AFCI protection in the kitchen includes the small appliance branch circuits, lighting and all individual appliance circuits, such as the garbage disposal, dishwasher, microwave, refrigerator and range hood.
Does garage need AFCI or GFCI?
Your garage needs to be GFCI protected, according to the 2008 and later editions of the NEC handbook. This includes garage door openers and garage lights that are connected to an outlet. In addition, AFCI protection is required for 5-amp and 20-amp 120/125-volt circuits.
Do garage lights need to be AFCI protected?
The shorter list is areas not requiring AFCI protection: unfinished basement areas, attached or detached garages, outdoor lighting and receptacles, accessory buildings and bathrooms are not required to be fed via AFCI protected circuit.
Do all garage receptacles need to be GFCI?
Yes, all garage outlets must be GFCI-protected-no exceptions. Since 2008, GFCI outlets have been required for “all 125-volt, single-phase, 15 and 20-amp outlets” in the garage. In fact, both the NEC (National Electric Code) and the IRC (International Residential Code) require this.
Does microwave require AFCI?
A dedicated 20-amp circuit is needed to feed the microwave oven. Since the appliance is plugged into an outlet, AFCI protection is required.
Where are AFCI outlets used?
AFCI outlets are recommended for the following locations in a house: family rooms, dining rooms, dens, bedrooms, closets, hallways, recreation rooms, sunrooms.
Does a refrigerator need a GFCI?
A refrigerator shouldn’t be plugged into a GFCI outlet. GFCI outlets are used in areas of the home with water or moisture. These include bathrooms, basements, and kitchens. This type of outlet is important because it reduces the risk of electrocution and electrical fires.