A sanitary tee is shaped like the letter ‘T’, while a Wye is similar to ‘Y’. Sanitary tee is used for horizontal to vertical transition, and Wye is used for combining 2 lines into one horizontal line to maintain a flow without causing clogging.
When would you use a sanitary tee?
A sanitary tee should be used when connecting a horizontal run, such as a waste arm to a vent stack or vertical riser. “If you think it’s expensive to hire a professional to do the job, wait until you hire an amateur.”Feb 24, 2013.
What’s the difference between a sanitary tee and a regular tee?
A sanitary tee is a plumbing fixture that allows liquids to drain while also allowing the plumbing system to vent. The fitting resembles a normal tee fitting; the sanitary tee, however, when viewed from the side will have a definite downward sweep to the center inlet.
Can you use a sanitary tee for venting?
Use a sanitary tee to connect a horizontal trap arm to a vertical drain and vent. The sweep on the santee must face down so that it sweeps toward the drain. If the diameter of the vent pipe is smaller than the drain pipe, glue a reducing fitting onto the upper barrel.
Can you use a sanitary tee for a cleanout?
A sanitary tee should be installed for the drain pipe connection. You will also need to install a vent to protect the sink’s trap. Re: tee into cleanout? The IPC/IRC will allow this as long as the clean out remains a clean out.
What is a wye used for?
Wye is used to connect a horizontal drainpipe to a vertical one. It reduces the entrained solid at the junction. It is also used to split branch lines. With a Wye, a line can be divided into two equal lines in two different directions.
What is sanitary tee?
Sanitary Tee or “Tee” means a “T” shaped fitting that allows sewage to flow into the horizontal outlet pipe by entering through the lower end of a vertical pipe. A sanitary tee is a form of a baffle.
Can I use a double sanitary tee?
Double sanitary tees may be used when the barrel of the fitting is at least two (2) pipe sizes larger than the largest inlet.
Which way does a sanitary tee go?
If you are using a sanitary tee to go from a horizontal vent pipe into a vertical vent the correct orientation is “upside down” from its normal usage. The curve of the tee should go from the horizontal direction curving up toward the roof.
What is a double wye used for?
A double-wye fitting may be used in horizontal drain lines. The use of 1/8th bend elbows at the outlets of the double-wye fitting to form a double-combination pattern is acceptable. The minimum slope of the barrel of the fitting shall be “/-inch per foot.
Can you put a San tee on its back for a vent?
The IPC allows the use of a san-tee or vent tee on its back to connect a dry vent to a fixture drain above the drains center line, or maybe i should say the IPC does not prohibit it.
Can a wye be installed horizontally?
IPC TABLE 706.3 “fittings for change of direction” says wye is okay for horizontal to horizontal.
Is a cleanout required under kitchen sink?
Cleanouts are generally required on horizontal branches of drain pipe, but because the P-trap has removable connections, it can serve as a cleanout, so you usually don’t need another one under the kitchen sink.
Can I tie a drain into a cleanout?
You may tie into the drain line through that cleanout providing you still retain a cleanout of the same size. Begin by removing the cap and thoroughly cleaning the femal threads of the existing cleanout with a wire brush.
Can a cleanout be used as a drain?
Cleanouts shall be installed at each change of direction greater than 45 degrees (0.79 rad) in the building sewer, building drain and horizontal waste or soil lines. An approved two-way cleanout is allowed to be used at this location to serve as a required cleanout for both the building drain and building sewer.
Where do you put a long sweep elbow?
Long sweep elbows are commonly used in residential and commercial construction to direct water from above-floor drains and sumps to the main drain line. They are a kind of a very long (and curved) pipe fitting that is used instead of a 90-degree elbow fitting to route wastewater.
Can a wye be installed backwards?
the fitting wye cannot even on it’s back, by code be reversed.
What is a wye pipe?
Pipe wyes are used to to allow one pipe to join another pipe at some degree or angle. As the name suggests, the pipe wyes are Y-shaped pipe fitting devices. They are a popular type of pipe fitting used in various industrial applications.
What is a sewer Wye?
sewer and drain (Sewer and Drain) pipe run and connects three lengths of pipe. This wye is used to add an intersection to the pipeline and connect three pipes of the same type and diameter size.
Can a shower and toilet share the same drain?
In the US, with modern regulations, in most municipalities, yes, they do. The water and solids from your toilet waste line and the water from your drains end up in the same sewer line, if you have access to a municipal sewer system.
How do you snake a double sanitary tee?
Insert one down each sink. Turn them both on simultaneously and they’ll inflate until they block up the sinks, at which point they’ll fill the plumbing in between the two and use pressure to push the blockage down the only remaining path.
What is a 1/8 bend in plumbing?
Similar to a 45 degree elbow, DWV PVC fittings use what are called 1/8 bends. This bend has standard HUB ends – meaning the pipe slides into each end. Designed for drain, waste, and vent applications.
Can a Fernco be used horizontally?
Under our code, we can use fernco’s where ever we feel, horizontal, vertical, diagonal, inverted, right side up, what ever you want to call it, we can use them there.
What is the difference between a wet vent and a dry vent?
A wet vent system drains the water from one fixture while venting the air from one or more other fixtures. A dry vent system only transports air. No water is carried. In other words, wet vents may vent one fixture and drain another, whereas dry vents usually just vent air from one fixture at a time.
Can toilet vent be upstream?
A toilet vent can be upstream. The purpose of the vent pipe is to allow the sewer’s gases to escape from the house’s roof rather than inside the house. A vent also allows oxygen to enter into the sewer pipes, which allows the waste to break down and prevents clogging.