Quick Answer: What Size Wire For A 30 Amp Circuit

For a maximum of 30 amps, you’ll need a wire gauge of 10. The most common household item that requires a 30 amp circuit is a central air conditioner.

How far can you run 10 gauge wire for 30 amps?

10-gauge wire can accommodate a 30-amp breaker until you reach 150 feet. At 150 feet or more, you should get 8AWG or 6AWG wire.

Can 12 gauge wire handle 30 amps?

You should not use a 30-amp circuit breaker on a 12-gauge wire. The circuit breaker installed on a circuit is of a specific size to protect a certain wire gauge. This higher current can damage the thinner wire, melt the insulation, cause short circuits, fire, and even lethal shock.

What size wire is needed for 30 amp 240 volt?

Use 12-gauge wire for a 20-amp circuit, 10-gauge for 30 amps, 8-gauge for 40 amps, and 6-gauge for 50 amps.

Will a 12 2 wire carry 30 amps?

Can You Use a 12-2 AWG for 30 Amps Circuit. Yes, based on the National Electric Code or NEC, you can use 12-2 AWG cables for THHN or THWN-rated wires. These cables are made for general purposes and can hold up to 194 degrees without taking any damage.

How far can you run 8 gauge wire for 30 amps?

10-gauge wire is usually used for short 30 amp runs. If you plan on going over 150 feet, 8-gauge wire or thicker will be needed.

Can you use a 30 amp breaker with 8 gauge wire?

Originally Answered: Can an 8-gauge wire handle 30 amps? Yes, it can. Under the NFPA Article 70 (National Electrcal Code), #8 wire is rated for 50 amps under certain conditions, however it is usually protected at 40 amps.

How many amps will a 12 2 wire carry?

Maximum Breaker Size is 30 amps. You can use a 20 amp circuit breaker with 12/2 Romex as 12/2 wire is rated for 20 amps.

What can I run off a 30 amp breaker?

Electric dryer, electric oven, medium or small A/C unit, electric range, 5 HP air compressor, electric arc welder, level 2 electric car charger (30 amp model), small electric heater, small electric instantaneous hot water heater, small hot tub, pool pump (3–5 HP).

How many amps is number 8 Romex good for?

Size & AMP Ratings NM, TW, & UF WIRE (Copper Conductor) SE CABLE (Copper Conductor) 12 AWG – 20 AMPS 6 AWG – 65 AMPS 10 AWG – 30 AMPS 4 AWG – 85 AMPS 8 AWG – 40 AMPS 2 AWG – 115 AMPS 6 AWG – 55 AMPS 1 AWG – 130 AMPS.

How many outlets can be on a 30 amp circuit?

20 outlets for 30 amp breaker as a rule of thumb of 1.5 amps per outlet.

Can wire gauge be too big?

If a wire gauge is “too big” then it is a lot more expensive and is harder to bend, as well as more difficult to attach with wire nuts or to switches. Other than that, not much of anything.

How far can you run 240 volt wire?

As an example, for a 120-volt circuit, you can run up to 50 feet of 14 AWG cable without exceeding 3 percent voltage drop.For 240-volt circuits: 14 AWG 100 feet 10 AWG 128 feet 8 AWG 152 feet 6 AWG 188 feet.

What size wire do I need for a 30 amp double pole breaker?

In the breaker panel it’s hooked up to a 30-amp double pole breaker with #12 wire. Inspector notes that #10 wire should be used for 30-amp circuits so that the wire does not melt before the breaker can do its job in an over-current situation.

How many wires can go on a 30 amp cord?

A 30 amp cord will have # 10 wiring in it. The 50 amp cord will have three # 6 wires in it to carry the current but the fourth wire is the ground wire and it will be of a smaller #8 gauge, which is adequate because it will only be used in the event of a short circuit and the breaker will trip soon thereafter.

How far can you run a 12 gauge wire?

You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.

How many breakers can I put in a 30 amp subpanel?

The maximum quantity of branch circuits can be determined with a load calculation. Two 15amp breakers or one 15amp and one 20amp can be used on a 30amp circuit.

What size wire do I need to run 300 feet?

for 300 feet for 100 amp rated service I would use Aluminum direct burial 1/0-1/0-1/0-1/0, the forth can be as low as #4 for the ground (but also in conduit, even if in conduit must still be rated underground wire and required by code also) Also note the size wire the breaker can handle, cannot cut strands to make fit, Jul 28, 2014.

What’s the difference between 10 2 wire and 10 3 wire?

In the case of 10/2 it’s a #10 hot (insulated black), #10 neutral (insulated white) and #10 ground (either bare or insulated green). In the case of 10/3 it’s two #10 hots (insulated black and red), one #10 neutral (insulated white) and one #10 ground (bare or insulated green).

Will 6-gauge wire fit in a 30 amp breaker?

“Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”Sep 18, 2017.

How do I know what gauge wire to use?

To determine what gauge wire you need, consider the carrying capacity and the amount of current the wire needs to conduct (measured in amperage or amps). Wire gauge is directly related to how many amps you need to run through it. The distance you need the wire to go can also impact the gauge of wire you need.

What gauge wire do I need 12v?

Maximum current (amps) in a 12V electrical circuit vs. size (AWG) and length of wire. American Wire Gauge (#AWG) Length (feet) Maximum Current (amps) 25 14 8 30 12 6 40 12 6.

How many amps does a TV use?

The average American TV is 50 inches and uses 0.95 amps at 120 volts. That works out to an average TV power consumption of 113 watts. In a given year, the average TV will use 142 kWh and cost a little over 17 dollars (assuming 5 hours of use per day).

What is the purpose of 12-2 2 Romex?

Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads.12-2-2 NM-B Cable Specifications*: Cable Type NM-B # of Conductors 4 Conductors w/ Ground Conductor Material Bare Copper Ampacity 20 Jacket Color Yellow.

How far can you run 12-2 on a 20 amp breaker?

But the voltage may drop too low for the motor to ever start. Originally Answered: How far can you run 12 gauge wire on a 20 amp circuit? About 400 feet. After that voltage drop is a factor and the gauge will have to be increased or the voltage increased.