Table of Contents
You can use a 20 amp circuit breaker with 12/2 Romex as 12/2 wire is rated for 20 amps.
Will a 12-2 wire carry 30 amps?
Can You Use a 12-2 AWG for 30 Amps Circuit. Yes, based on the National Electric Code or NEC, you can use 12-2 AWG cables for THHN or THWN-rated wires. These cables are made for general purposes and can hold up to 194 degrees without taking any damage.
Can 12 AWG handle 30 amps?
Can You Use a 30-Amp Breaker On 12-Gauge Wire? You should not use a 30-amp circuit breaker on a 12-gauge wire. The circuit breaker installed on a circuit is of a specific size to protect a certain wire gauge. A larger breaker on a thinner wire will allow more current over the wire before tripping.
How many watts can you run on a 12-2 wire?
12 gauge wire is rated for 20 amps peak, 16 amps sustained. On a 120 volt circuit, 120 * 16 = 1920 watts. On a 240 volt circuit, 240 * 16 = 3840 watts.
Can 12 gauge wire handle 40 amps?
RULES OF THUMB “Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”Sep 18, 2017.
How far can you run 12 gauge wire on a 20 amp circuit?
You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.
Can you use 12 2 wire to run 220?
It’s really about their ampacity (current carrying capacity under normal conditions). Perhaps you mean 12/2 wire to be used with 220 Volts power supply.so,yes you can. size of conducting wire is independent of the voltage with which it has to be used. Higher the voltage, more is the thickness of the insulation.
What is the largest breaker for 12 gauge wire?
The rating for a 12 gauge wire is 25 Amps. Unless following an exception for motor loads, NEC only allows for it to be protected at a max of 20 Amps. I would split the load and install a separate circuit.
What size wire do I need for 50 amp?
50 AMP Wire Size For a maximum of 50 amps, you’ll need a wire gauge of 6. Fifty amp breakers are most often used to power many different appliances. However, a kitchen oven can alone require 50 amps. Many electric dryers also require a 50 amp breaker.
What does 12 AWG wire mean?
The wire gauge simply refers to the sizing of the wire (the thickness). 12 AWG is equivelent in size to 12 gauge wire, but “12 gauge” wire can be a variety of things whereas “12 AWG” is 12 gauge wire made according to the AWG standard.
Can you use 12-2 Romex for lights?
2 Answers. As long as you have a 15A circuit breaker on that circuit, it’s OK to use 12/2 NM cable for your lights.
What is the purpose of 12-2 2 Romex?
Applications: Non-metallic sheathed NM-B cable is used in normally dry installations in residential wiring, as branch circuits for outlets, lighting and other residential loads.
How many outlets can you run on a 12-2 wire?
For general use receptacles, In commercial buildings it is limited to 180VA per duplex or single receptacle, therefore on a 12/2 Romex cable not otherwise subject to ampacity derating and protected by a 20 amp circuit breaker, that would allow a maximum of 13 receptacles.
What type of Romex should I use?
The following NEC regulations apply to Romex conductors: Wire Gauge or Type Rated Amperage Common Uses 14-2 Romex 15 A Lighting Circuits 12-2 Romex 20 A Lighting and Outlet Circuits, refrigerator 10-2 Romex 30 A Electric water heater, baseboard heaters 10-3 Romex 30 A Electric Clothes Dryer.
What size wire should I use for a 15 amp breaker?
A 15-amp circuit is usually served by 14-gauge wire and is protected by a 15-amp circuit breaker or fuse. A 20-amp circuit, protected by a 20-amp breaker or fuse, must be served by 12-gauge or 10-gauge wire.
What gauge wire do I need 12v?
Maximum current (amps) in a 12V electrical circuit vs. size (AWG) and length of wire. American Wire Gauge (#AWG) Length (feet) Maximum Current (amps) 25 14 8 30 12 6 40 12 6.
How long can you run a 12 2 wire?
You can run 50′ on a 12 gauge wire. I can’t imagine why you would want to run a number 12 any further than 50′. If you have to go that far you are better to have 30–50+ amp with 2 phases’ and a sub panel with breakers.
What size wire do I need to run 400 feet?
It should be #6 or larger depending on the distance from the panel to the load and the type of load. For a straight resistive load you’ll likely have to go to #4 wire.
How long can you run Romex?
As an example, for a 120-volt circuit, you can run up to 50 feet of 14 AWG cable without exceeding 3 percent voltage drop.For 240-volt circuits: 14 AWG 100 feet 12 AWG 120 feet 10 AWG 128 feet 8 AWG 152 feet 6 AWG 188 feet.