Quick Answer: What Amp Breaker For Water Heater

Electric water heaters require a 240-volt dedicated circuit, which serves only the water heater and no other appliances or devices. The circuit wiring typically includes a 30-amp double-pole breaker and 10-2 non-metallic (NM) or MC cable.

What size breaker do I need for a 40-gallon hot water heater?

With our answer, a 40-gallon water heater needs at least a 25-amp breaker, the closest to the amperage value. However, I highly recommend using 30-amps for a safer breaker size.

What size breaker do I need for a 50 gallon hot water heater?

The standard for water heater circuits is #10, two conductors with ground (10/2) and a 30 amp circuit breaker for a water heater. If you are running cable anyway, just run #10 and replace the breaker so it’s done right, once and for all.

Can you use a 20 amp breaker for a water heater?

A water heater with a 4500-watt heating element requires a 10/2 wire with a 30 amp (240volt) circuit breaker. The 3800-watt heating element can be wired with a smaller 12/2 wire and a 20 amp circuit breaker.

Can I use a 40 amp breaker for water heater?

You cannot put a 40A breaker on #10 wire. If you are sure there is (at least) #8 wire all the way from the breaker to the water heater, you can just replace the 30A breaker with a 40A breaker, but if and only if you have verified the size of the wire throughout the entire circuit.

How many amps is a double pole 30 amp breaker?

A 30 amp double pole or two pole breaker gives you a total of 30 amps on each legbefore it is supposed to trip. In the cases where a double pole breaker feeds a single load, such as for stove, clothes dryer, water heater etc. the majority of the load will be provided across the two halves of the split phase service.

Can I use 12 gauge wire on a 30 amp breaker?

You should not use a 30-amp circuit breaker on a 12-gauge wire. The circuit breaker installed on a circuit is of a specific size to protect a certain wire gauge. This higher current can damage the thinner wire, melt the insulation, cause short circuits, fire, and even lethal shock.

What size breaker do I need for a 4500 W water heater?

The right circuit breaker for this appliance with 4500 watts at 240 volts is either 25 amps or 30 amps. If the water heater isn’t rated as “continuous load”, then it would have been fine to use 100% of the circuit breaker’s rating.

Can you use 12 2 wire for a water heater?

Most electric water heaters installed in North America require a 30-ampere grounded 240-volt connection which requires a pair #10 copper wires PLUS a ground wire. Copper 12/2 wire is rated for a maximum of just 20-amperes and would be inadequate both in current capacity and for lacking a ground wire.

Does Square D make a 25 amp breaker?

Square D QO 25-Amp 1-Pole Standard Trip Circuit Breaker.

What size breaker do I need for my water heater?

Multiply the value for current by 125 percent to determine the size of the breaker you need for the heater. A 1500-watt heater on a 120-volt circuit thus needs a breaker of 15.6 amps. Because a 15-amp breaker would be too small, you need a breaker with the next highest rating, which is 20 amps.

What size breaker do I need for a 30 gallon water heater?

The branch circuit needs to be calculated at 125% of the rated ampacity for this type of water heater to be considered a continuous load. In order to work on a 20 Amp OCPD, you will need a 25 or 30 Amp circuit.

Is there a breaker on a hot water heater?

You can cut off power to your hot water heater in either one of two ways: Locate your water tank and turn the power to it OFF by pulling the electrical plug out of the wall socket. Another way to turn the power off is to flip the circuit breaker (the breaker that’s labeled “water heater”) to the OFF position.

Can I use a 50 amp breaker for a 30 amp water heater?

30 amps is where a 30 amp breaker should cut off, and to avoid that, you should only use 80% of the breaker’s capacity. So for a 30 amp breaker, you shouldn’t be using more than 24 amps. Using a 50 amp breaker and a dedicated outlet ensures that you don’t exceed the capacity of the circuit with that appliance.

Can I use a 40 amp breaker for a 50 gallon water heater?

Yes, if AND ONLY IF the wires from the breakers to the water heaters are sufficient to carry 40 amps (e.g. 8-gauge 90C THHN copper). The largest residential heating elements for a tanked water heater are 7000 watts.

What size wire do I need for a 40-gallon electric water heater?

An average 40-gallon electric water heater requires 12 gauges of wire. You cannot use a 6 gauge or 10 gauge wire in that case. The current will overflow and the wire will start melting.

Is a double 30 amp breaker the same as a 60 amp breaker?

A main breaker is a large-amperage double breaker, same as any double breaker in the breaker box, except it supplies power to each busbar. So your question is like asking if you can draw 60 amps off a 30 amp double breaker the answer is NO.

Is a double pole 50-amp breaker 100 amps?

It is 100 amp. And the two 50 amps breakers that are tied together are 50 amps, not 50 + 50 = ! 00. That 2 pole 100 amp CB can provide either 100 amps @ 240 volts or 200 amps @ 120 volts but in answer to your question as Chris stated it’s 100 amps.

Does a double 30 amp breaker equal 60 amps?

A main breaker is the same as any double breaker in the box, except that it supplies power to each busbar. The answer is no if you want to draw 60 Amps off a 30 Amp double breaker.