What Amp Breaker For Hot Water Heater

Electric water heaters require a 240-volt dedicated circuit, which serves only the water heater and no other appliances or devices. The circuit wiring typically includes a 30-amp double-pole breaker and 10-2 non-metallic (NM) or MC cable.

What size breaker does a 40-gallon water heater need?

With our answer, a 40-gallon water heater needs at least a 25-amp breaker, the closest to the amperage value. However, I highly recommend using 30-amps for a safer breaker size.

Can you use a 20 amp breaker for a water heater?

A water heater with a 4500-watt heating element requires a 10/2 wire with a 30 amp (240volt) circuit breaker. The 3800-watt heating element can be wired with a smaller 12/2 wire and a 20 amp circuit breaker.

How many amps does a 50 gallon water heater pull?

A typical 50 gallon electric water heater runs at 4500 watts. In an electric circuit of 240 volts, 4500 watts is equivalent to 18.75 amps.

Can I use a 40 amp breaker for a 30 amp water heater?

If you are sure there is (at least) #8 wire all the way from the breaker to the water heater, you can just replace the 30A breaker with a 40A breaker, but if and only if you have verified the size of the wire throughout the entire circuit.

Can I use a 40 amp breaker for a hot water heater?

Can I use a 40 amp breaker for a water heater? – Quora. Yes, if AND ONLY IF the wires from the breakers to the water heaters are sufficient to carry 40 amps (e.g. 8-gauge 90C THHN copper). The largest residential heating elements for a tanked water heater are 7000 watts.

How many amps is a double pole 30 amp breaker?

A 30 amp double pole or two pole breaker gives you a total of 30 amps on each legbefore it is supposed to trip. In the cases where a double pole breaker feeds a single load, such as for stove, clothes dryer, water heater etc. the majority of the load will be provided across the two halves of the split phase service.

What size breaker do I need for a 50 gallon electric water heater?

The standard for water heater circuits is #10, two conductors with ground (10/2) and a 30 amp circuit breaker for a water heater. If you are running cable anyway, just run #10 and replace the breaker so it’s done right, once and for all.

What size breaker do I need for my water heater?

Multiply the value for current by 125 percent to determine the size of the breaker you need for the heater. A 1500-watt heater on a 120-volt circuit thus needs a breaker of 15.6 amps. Because a 15-amp breaker would be too small, you need a breaker with the next highest rating, which is 20 amps.

What size breaker do I need for a 4500 watt hot water heater?

The right circuit breaker for this appliance with 4500 watts at 240 volts is either 25 amps or 30 amps. If the water heater isn’t rated as “continuous load”, then it would have been fine to use 100% of the circuit breaker’s rating.

Can you use 12 2 wire for a water heater?

Most electric water heaters installed in North America require a 30-ampere grounded 240-volt connection which requires a pair #10 copper wires PLUS a ground wire. Copper 12/2 wire is rated for a maximum of just 20-amperes and would be inadequate both in current capacity and for lacking a ground wire.

What size wire do I need for a 50 gallon hot water heater?

A 40-gallon heater requires 12-gauge wire. On the other hand, you need 6-gauge wire for a 50-gallon water heater. Like the amperage rating, the bigger the tank size, the thicker the wire.

Can I use a 50 amp breaker for a 30 amp water heater?

30 amps is where a 30 amp breaker should cut off, and to avoid that, you should only use 80% of the breaker’s capacity. So for a 30 amp breaker, you shouldn’t be using more than 24 amps. Using a 50 amp breaker and a dedicated outlet ensures that you don’t exceed the capacity of the circuit with that appliance.

What is a 40 amp breaker used for?

Double-pole breaker The 15-amp and 20-amp breakers often handle baseboard heaters, 30-amp serve water heaters and electric dryers, 40- and 50-amp are for electric ranges, and the 70-amp could serve a large air conditioner or a subpanel.

What size wire do I need for a 40-gallon electric water heater?

An average 40-gallon electric water heater requires 12 gauges of wire. You cannot use a 6 gauge or 10 gauge wire in that case. The current will overflow and the wire will start melting.

Can I replace a 40 amp breaker with a 50 amp?

3 Answers. In general, no. Installing a 50A breaker on wiring only designed to support 40A is dangerous and can result in a house fire.

What happens if you oversize a breaker?

If there is a direct short in an appliance a breaker will kick off even if oversized, but if there is simply a crossed or burned wire it may not turn off. This would cause a possible shock hazard. It is best to size the breaker slightly above the total current draw of the appliance.

What size breaker do I need for a 30 gallon water heater?

The branch circuit needs to be calculated at 125% of the rated ampacity for this type of water heater to be considered a continuous load. In order to work on a 20 Amp OCPD, you will need a 25 or 30 Amp circuit.