QA

How To Light Pilot Light On Furnace

Can I relight the pilot light by myself?

If your pilot light goes out, your furnace will not be able to produce heat because its burners will not ignite. Often, homeowners can relight the pilot themselves.

Can you manually light a pilot light?

Use a grill lighter or long match to light the pilot light valve at the bottom of the oven. Some ovens are designed to be manually lit at each use. In this case, slowly turn the temperature knob while holding the flame to the pilot light valve. Close the oven door after the pilot light ignites.

How do I know if my furnace pilot light is out?

How to Tell If the Pilot Light Is Out Locate the front cover panel on your furnace. It should be a little door that’s easily visible. If your pilot light is on, it should be easy to see – your eyes will be drawn to the little flame. If you don’t see a flame, your pilot light is out. If there is a flame, check the color.

Why is my pilot light not staying lit on my furnace?

If your pilot light won’t stay alight, it might be the thermocouple. Sometimes dust buildup collects on the thermocouple and blocks the sensor. Try cleaning the thermocouple and then relighting the pilot light. If it continues to go out, the thermocouple might need to be replaced.

Should the pilot light always be on in a gas furnace?

Most furnaces with electronic ignition have a device called a hot surface igniter. The difference is that the flame is only lit (by an electronic spark) when your furnace is ready for a heating cycle. When the pilot light is not needed, it is completely off, saving you money on gas.

How do I get my pilot light back on?

How Can I Restart My Pilot Light? Step 1: Turn off your furnace. Step 2: Locate your gas valve. Step 3: Hold down the red button. Step 4: Light the pilot light. Step 5: Let go of the button. Step 6: Turn your gas back on. Step 7: Turn your furnace back on.

What causes a pilot light to go out?

Some of the possible serious reasons for pilot lights to go out include loose or broken gas valves, thermocouples or heat exchangers, faulty venting, low gas pressure, or high winds. If you believe there is a serious problem, don’t hesitate to contact a professional.

How much does it cost to relight a pilot light?

Most service providers will charge a standard fee per visit that typically covers the cost to relight a gas water heater. This service call price can range from $80 to $100.

What would cause a gas furnace not to ignite?

The Pilot Light (Faulty Ignition Sensor) The pilot light or ignition sensor is usually the most common issue when your furnace will not ignite. This is typically the problem if you can hear your furnace click on but it does not fire up. If the sensor or ignitor is dirty, it will need to be cleaned.

How do you restart a furnace?

How to Reboot a Furnace Change the Filter. Before you do anything, check the furnace filter. Check the Pilot Light. If the pilot light is off, your furnace can’t get the spark necessary to light the boilers. Turn the Furnace Off and Back On Again. Call a Certified HVAC Professional.

How do you reset an automatic pilot light?

Press the gas control knob down all the way and hold it in the depressed position. If you have no igniter, move the match or barbecue lighter flame to the end of the pilot tube; the pilot flame should light immediately.

Why is my furnace not blowing hot air?

First, check to make sure the thermostat is set correctly. You will want to make sure that the fan control is set to auto, and not ‘on’. If the thermostat appears set correctly, turn off your heater at the thermostat and check the filter. If the filter is dirty, replace it.

Will gas leak if pilot light is off?

If the pilot light goes out on a storage or instantaneous hot water heater, space heater or a ducted heater, you will not have a gas leak. This is because all modern gas appliances with pilot lights have a fail-safe device that closes off the gas to the appliance in the case when the pilot may go out.

Should you turn off the pilot light on a gas furnace?

Most modern mid to high efficiency gas furnaces no longer have a pilot light. It’s been replaced by an electronic ignition. As a result, the furnace will not need to continuously burn gas in order to keep a pilot light going, making it unnecessary to turn off your furnace for the summer.

How do you fix a gas fire that keeps going out?

Easy DIY Fix: Gas Fireplace Won’t Stay Lit Before You Begin: Is Your Pilot Light Lit Inside Fireplace? The Fix: Pilot Light to Gas Fireplace Won’t Stay Lit. Check Your Thermopile Output with the TH/TP Contacts. Don’t Replace Your Thermopile or Thermocouple Right Away. Cleaning the Thermopile. Re-test the Cleaned Thermopile.