How far above roof does wood stove pipe need to be?

In essence, any chimney, stove pipe or other heating exhaust vent should be 3 feet (1 meter) above the roofline or 2 feet (61 centimeters) above any part of the building in a 10-foot (3-meter) radius.

How close can stove pipe be to ceiling?

At least 36 inches of clearance must be allowed between the top of a stove and an unprotected ceiling. Brick or stone provide little or no protection for a combustible wall since they are good conductors of heat.

Is a cathedral ceiling the same as a vaulted ceiling?

A vaulted ceiling slopes upward from both sides to form a peak. On the other hand, cathedral ceilings are defined by their symmetry: they feature two equal sloping sides that meet at a higher point in the middle and often conform to the shape of the roof.

Can double wall stove pipe go through roof?

You can use double wall or single wall connector pipe between the ceiling and stove depending on your application and clearances. Once to the ceiling you must transition to class A (expensive) stainless material and go all the way to the chimney cap with it.

How do you seal a stove pipe on a roof?

You will need to seal the base of the pipe boot to your roof with silicone or urethane roofing sealant. This product should not touch the stovepipe, so high temp silicone is not necessary. Use whatever product is recommended for your roofing material. The boot does not need any sealant where it meets the stovepipe.

Does a wood stove pipe have to go straight up?

The pipe should be as straight and short as possible, with sections properly secured. If it must have angles, limit them to one or, at the most, two sweeping 90-degree elbows or the equivalent. The horizontal portion of the pipe should rise not less than one-quarter inch to the linear foot, to insure a good draft.

How high does a wood burner flue have to be?

Chimney Heights and Termination The minimum chimney height recommended for minimum performance of wood burning and multi fuel appliances is 4.5 m from the top of the appliance to the top of the chimney. It is best to position the chimney, so that it goes straight up as near to the roof ridge as possible.

How high is chimney above roof peak?

This rule means that your chimney’s shortest side needs to be at least 3 feet above the roof penetration, and its top has to be 2 feet higher than any part of the building that’s within 10 feet.

How do you fireproof a wall behind a wood stove?

Common fireproof wall ideas for behind a stove include stone, brick and tiles. The look of a wood burning stove can be enhanced by using a faux panel (such as a stone veneer look) or using a fireback.

How much space should be between wood burning stove and wall?

The standard clearance recommended by the National Fire Protection Agency is 36 inches. This means that the back of the stove should be 36 inches away from any combustible material, such as woodwork, unprotected walls, furniture and even firewood.

What do you put on the wall behind a wood stove?

The fireback is a traditional heat shield for a stove The solution of replacing the back wall with a heat-resistant material, such as heat-resistant stones or a wood stove heat shield, is often cumbersome and not always beautiful.

Can you vent a wood-burning stove horizontally?

Venting is an important component of all stoves. And wood, gas, and pellet stoves have different venting systems. For instance, wood-burning stoves will always be vented through the roof of your house, but pellet-burning stoves can be vented vertically through the roof, or horizontally through the wall to the outdoors.

What is needed for a wood stove chimney?

Masonry walls for chimneys less than 30 feet high must be at least 4 inches thick. If stone is used for the wall, a 12-inch minimum thickness is needed. A chimney that is exposed directly to the elements should have walls at least 8 inches thick to provide added strength for withstanding weathering and wind.

Can you vent a wood stove into a chimney?

Stoves can be added to a fireplace in several ways. Free-standing stoves can be installed so that the stove pipe enters into the fireplace chimney above the damper, through the damper or into the firebox below the damper. Properly designed stoves can also be inserted into the fireplace opening.

Does wood stove pipe have to be double wall?

Single-Wall stove pipe can be installed as long as you have a 18″ clearance to a wall, ceiling or floor. If your clearance to combustibles is less than 18″, you have to install double-wall stove pipe. If you have a clearance under 18″ then you must install double-wall pipe.