How Many Amps Does A Hot Water Heater Pull

Most electric water heaters use 18.8 amps with 240 volts and a 4,500 watt heating element. A gas water heater uses less amps—about 12 Amps with 115 volts. The average residential container heater has a 40-gallon tank and usually requires a 30-amp breaker.

How many amps does a 50 gallon water heater use?

A typical 50 gallon electric water heater runs at 4500 watts. In an electric circuit of 240 volts, 4500 watts is equivalent to 18.75 amps.

How many amps does a 40-gallon water heater use?

For a 40-gallon heater, the average capacity is 4500 Watts with 240 Volts. Again, I = P/V; 4500W/240V = 18.75 amps. Then considering the continuous load (125% x 18.75A), we’ll get a total of 23.4 amps. With our answer, a 40-gallon water heater needs at least a 25-amp breaker, the closest to the amperage value.

What size breaker is needed for a 50 gallon electric water heater?

The standard for water heater circuits is #10, two conductors with ground (10/2) and a 30 amp circuit breaker for a water heater.

What size breaker do I need for a hot water heater?

Electric water heaters require a 240-volt dedicated circuit, which serves only the water heater and no other appliances or devices. The circuit wiring typically includes a 30-amp double-pole breaker and 10-2 non-metallic (NM) or MC cable.

Can I use a 40 amp breaker for water heater?

You cannot put a 40A breaker on #10 wire. If you are sure there is (at least) #8 wire all the way from the breaker to the water heater, you can just replace the 30A breaker with a 40A breaker, but if and only if you have verified the size of the wire throughout the entire circuit.

How many amps does a 30 gallon electric water heater use?

The branch circuit needs to be calculated at 125% of the rated ampacity for this type of water heater to be considered a continuous load. In order to work on a 20 Amp OCPD, you will need a 25 or 30 Amp circuit.

Is there a breaker on a hot water heater?

You can cut off power to your hot water heater in either one of two ways: Locate your water tank and turn the power to it OFF by pulling the electrical plug out of the wall socket. Another way to turn the power off is to flip the circuit breaker (the breaker that’s labeled “water heater”) to the OFF position.

What size breaker do I need for a 20 gallon electric water heater?

Electric water heaters require a dedicated 240-volt dedicated 30-amp circuit and a 10-2 non-metallic (NM) or MC cable. This means the breaker only powers the water heater and no other appliances. A 30-amp circuit breaker can power all 4500watt water heaters regardless of gallon size.

What size breaker do I need for a 240-volt heater?

Adding a 240-volt baseboard heater usually requires a new 20- or 30-amp double-pole circuit breaker and new circuit wiring to supply one or more heater units. This is a dedicated circuit that serves only the heater.

How many amps does a 240 volt water heater use?

Most electric water heaters use 18.8 amps with 240 volts and a 4,500 watt heating element. A gas water heater uses less amps—about 12 Amps with 115 volts. The average residential container heater has a 40-gallon tank and usually requires a 30-amp breaker.

What size wire would you run for a 30 amp breaker connected to a electric water heater?

Electrical wires Since the generic breaker size for water heaters is 30-amps, the best wire size is a #10 American Wiring Gauge (AWG).

Does Square D make a 25 amp breaker?

Square D QO 25-Amp 1-Pole Standard Trip Circuit Breaker.

How many amps is a double pole 30 amp breaker?

A 30 amp double pole or two pole breaker gives you a total of 30 amps on each legbefore it is supposed to trip. In the cases where a double pole breaker feeds a single load, such as for stove, clothes dryer, water heater etc. the majority of the load will be provided across the two halves of the split phase service.

How much does a 30 amp breaker cost?

The average cost to install a new circuit breaker is $187. The cost is as low as $130 for 15 amp to 30 amp breakers and as high as $280 for breakers up to 200 amps or when the circuit breaker is an older one with limited availability.

How many amps does a 110 hot water heater use?

The standard amperage for an electric water heater is 18.8 Amps with 240Volts, 4500 Watt.

Can I use a 50 amp breaker for a 30 amp water heater?

30 amps is where a 30 amp breaker should cut off, and to avoid that, you should only use 80% of the breaker’s capacity. So for a 30 amp breaker, you shouldn’t be using more than 24 amps. Using a 50 amp breaker and a dedicated outlet ensures that you don’t exceed the capacity of the circuit with that appliance.

What size breaker do I need for AO Smith 40-gallon water heater?

A 40-gallon water heater should have an average 4500 Watt capacity and 240 V emf. Thus, a 25 or 30A breaker is sufficient for a 40-gallon breaker. However, for your safety, we recommend getting a 30A breaker.

Can I use a 40 amp breaker for a 50 gallon water heater?

Yes, if AND ONLY IF the wires from the breakers to the water heaters are sufficient to carry 40 amps (e.g. 8-gauge 90C THHN copper). The largest residential heating elements for a tanked water heater are 7000 watts.

How many amps does a Rheem water heater use?

RHEEM 240V General Purpose Electric Tankless Water Heater, 8,000 W Watts, 33 A Amps – Water Heaters – 53UJ83|RTEX-08 – Grainger.

How many amps does a 10 gallon water heater pull?

Rheem PROE10 1 RH POU $864.17 10 gal., 120 VAC, 16.7 A Amps, Residential Mini Tank Water Heater | Zoro.com.

How many amps does an instant hot water dispenser use?

How Many Amps Does A Tankless Water Heater Use? (42-167 Amps) Electric tankless heaters use exclusively electricity to heat up water.