How High Above The Garage Floor Are Receptacles Located

Garage electrical outlet location: In the garage electrical outlets should be 18″ or more above floor level.

How high should outlets be in a garage?

Many contractors place outlets 12 to 18 inches above the floor because that height suits most people, not because the NEC demands it. That being said, the American Disabilities Act expects homeowners to place wall receptacles at least 15 inches above the floor.

What is the code for electrical outlets in a garage?

As of the 2017 NEC, newly constructed garages need at least one dedicated 120-volt 20-amp circuit that serves only the garage. This circuit may also power receptacles mounted on the exterior of the garage.

Where do you put outlets in a garage?

Standard outlets are spaced apart, a foot or so above the floor. If you plan on adding workbenches along the walls, you’ll also want outlets at the same above-the-counter height as in a kitchen. This way, you won’t have to drop a cord behind the bench top.

How high should an outlet be from the floor?

Standard Height for Outlet Boxes The standard height for wall outlet boxes is about 12 inches from the top of the floor covering to the bottom of the receptacle box (or 16 inches to the top of the box).

Do I need GFCI outlets in garage?

GFCI protection is required for 125-volt to 250-volt receptacles supplied by single-phase branch circuits rated 150 volts or less to the ground. GFCI receptacles are required in bathrooms, garages, crawl spaces, basements, laundry rooms and areas where a water source is present.

Do garages need tamper proof receptacles?

Receptacles for garage-door openers located more than 5½ feet above the floor are required to be tamper-resistant. Floor receptacles located more than 18 inches from the wall are required to be tamper-resistant, even though 210.52 does not specify these receptacles as required receptacles.

How many outlets can be on a 20 amp circuit in a garage?

The answer to the question how many outlets on a 20 amp circuit is ten outlets. Always comply with the 80% circuit and breaker load rule, allowing a maximum load of 1.5 amps per receptacle. Remember that your circuit, wire sizes, and outlets must be compatible to avoid overheating and electrical hazards.

How many outlets do I need for a 2 car garage?

However, the code is just a minimum set of installation rules. The basic rule for garage receptacles is that one receptacle outlet needs to be installed in each vehicle bay and not more than 5 ½ feet above the floor.

Can Romex be exposed in garage?

No, you cannot expose Romex wires or non-metallic sheath wires in the detached garage or anywhere. Because it’s not safe to expose it on the outside. Besides, it goes against the National Electrical Code or NEC.

How do you add a receptacle in the middle of a run?

To start, turn off the power to the existing outlet at the breaker panel, and test to ensure it’s off. Then, remove the outlet and detach the wires. Install the box for the new outlet, remove the “incoming” wires from the old box, and run them into the new one.

How many receptacles can be on a 15 amp circuit?

Technically, you can have as many outlets on a 15 amp circuit breaker as you want. However, a good rule of thumb is 1 outlet per 1.5 amps, up to 80% of the capacity of the circuit breaker. Therefore, we would suggest a maximum of 8 outlets for a 15 amp circuit.

Why do electricians install outlets upside down?

Electricians may position the outlet in an upside-down position so that you can quickly identify the switch-controlled receptacle. Since it stands out visually to most people right away – it provides convenience to the occupants to easily remember which outlet is switch controlled.

What is code height for electrical switches?

Many builders position switch boxes so the bottom of the box is 48 inches above the floor. To satisfy the accessibility requirements of the Fair Housing Act, however, the switch itself should be no more than 48 inches from the floor.

Do I need arc fault breakers in a garage?

The 2017 National Electrical Code (NEC) requires the protection of an arc fault circuit interrupter (AFCI) for 15 and 20 amp circuits in all newly built residential areas, but they are not needed in bathrooms, garages, or outdoor areas.

Where should I put GFCI in garage?

The actual verbiage from the NEC states that GFCI outlets be installed in: “Garages, and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use.”Mar 20, 2018.

How many outlets can be lighted on one branch?

Although there’s no limit on the number of lighting and/or receptacle outlets on dwelling general-purpose branch circuits, the NEC does require a minimum number of circuits to be installed for general-purpose receptacles and lighting outlets [210.11(A)].

Where are tamper resistant outlets not?

Exception: Receptacles in the following locations aren’t required to be tamper-resistant: Receptacles located more than 5½ ft above the floor. Receptacles that are part of a luminaire or appliance.

Is it code to use tamper resistant outlets?

Tamper-Resistant Receptacles (TR): All 15- and 20-ampere receptacles in a home are now required to be tamper-resistant. Tamper-resistant receptacles have built-in shutters that prevent children from inserting foreign objects in the receptacle slots.

Do I need weather resistant GFCI in garage?

Weather Resistant GFCI Required by 2008 National Electrical Code for use in damp or wet areas including: Patios, decks, porches, pool areas, garages, yards, and other outdoor damp locations. When installing a weather resistant GFCI in a damp location remember that you must also use a weather resistant cover.