Table of Contents
If your pilot light won’t stay alight, it might be the thermocouple. Sometimes dust buildup collects on the thermocouple and blocks the sensor. Try cleaning the thermocouple and then relighting the pilot light. If it continues to go out, the thermocouple might need to be replaced.
Why does my gas pilot light keep going out?
Some of the possible serious reasons for pilot lights to go out include loose or broken gas valves, thermocouples or heat exchangers, faulty venting, low gas pressure, or high winds. If you believe there is a serious problem, don’t hesitate to contact a professional.
When I release the pilot button the flame goes out?
If you’re able to light the pilot light, but it goes out when you release the control knob, the thermocouple probably needs replacing. The thermocouple is a safety device that shuts off gas flow if it senses the pilot light is out, but when damaged it loses its regulatory ability.
How much does it cost to replace a thermocouple?
It costs $150 to $250 to replace a thermocouple. It checks to make sure the pilot light is on. It will shut the gas off if it’s not.
Can you clean a thermocouple?
Yes, you can clean a thermocouple, but the task must be done with a light touch. Remove the thermocouple from the process assembly, using a steel wool or emery cloth, lightly clean the tip removing any build up.
Why won’t the pilot stay lit on my wall heater?
The Pilot Won’t Stay Lit A pilot that won’t stay lit could be the result of a blockage in the pilot tube. Turn off the gas, clear the tube with compressed air, and relight the pilot. If that doesn’t work, you may need to call a repairman to come and install a new thermocouple.
Why does my pilot light keep going out after replacing thermocouple?
If your water heater pilot won’t stay lit even after replacing the thermocouple, you most likely have a faulty gas control valve. It is a sign that the valve is failing to open and allow gas to flow to the pilot. You could also be dealing with a tripped or faulty thermal switch.
Can I replace a thermocouple myself?
1 cause of pilot lights that won’t stay lit is a worn-out thermocouple. It’s easy to replace and a new one costs $5 to $10. Then detach the thermocouple from the burner and take it with you to the home center or hardware store to ensure you buy the right replacement.
How long do thermocouples last?
How to Tell if You Have a Bad Thermocouple? Thermocouples can last up to 10 years if properly installed and maintained, while furnaces can last 15-20 years, although either may wear out sooner in multifamily units.
Why is my thermocouple not working?
If the appliance has a thermocouple, the problem may be a faulty thermocouple. The thermocouple, which operates as a safety device, turns the gas supply off when the pilot light goes out. When a thermocouple fails, the pilot light won’t stay lighted. A burned out or broken thermocouple should be replaced.
How do you troubleshoot a thermocouple?
Importantly, always make sure the tip of the thermocouple is directly in the pilot flame. If the tip is in the flame, you have held the nob on the gas valve down for longer than a minute, the pilot flame is strong and steady, and the pilot still does not stay lit, then you likely have a problem with the gas valve.
Why will my furnace not stay lit?
Probably the most common issue when dealing with a furnace that will not stay lit or ignite consistently is a dirty flame sensor. The flame sensor acts as a communication vehicle with the circuit board and tells it when a flame is lit inside the furnace.
Why does my furnace flame keeps going out?
Your furnace has a limit switch that keeps it from running if the heat exchanger is too hot. Dirty filters, closed or blocked vents and other blockages in airflow are common causes of an overheated furnace. A bad limit switch. The limit switch may be bad and need to be replaced.
How do you bypass a thermocouple?
To bypass the thermocouple: Move the tilts switch wire aside. Remove your thermocouple from the heater using an 8mm wrench. Pull the valve housing aside using your 13mm socket wrench. Remove the valve using your pliers. Put your thermocouple back into position.
Can a thermocouple work intermittently?
In electrical circuits, the most unreliable points are electrical connections. So, if in a thermocouple circuit any of the connections suffer from corrosion or lack of intimate metal-to-metal contact, intermittent operation will result.
What do thermocouples do?
Thermocouples are sensors used to measure temperature. A thermocouple consists of two wires, or wire legs, made from different metals. The legs are welded together at one end, into a junction, where the temperature is measured. A voltage is created when the junction senses a change in temperature.
How do you clean a clogged pilot light?
Use your pliers or wrench to remove the pilot light and thermocouple from the bracket. Using the wire brush, brush away the carbon buildup and soot from both components. For hard to reach areas and stubborn buildup, use the metal file. Wipe away dust with a soft cloth or burst of compressed air.