Quick Answer: Where To Buy Limit Switch For Furnace

How much does a high limit switch cost for a furnace?

You will need to buy a high limit switch that is produced by the same manufacturer as your furnace unit. Depending on who your OEM is, this component could roughly cost you anywhere from $4 to $25.

Can you run a furnace without a limit switch?

Without a functioning furnace limit switch, a furnace would not be able to regulate the temperature in conjunction with a thermostat. Typically, a furnace limit switch consists of an exterior plate and a temperature probe that lives inside the furnace housing.

How much does a furnace switch cost?

Furnace Pressure Switch Replacement Your furnace has multiple safety switches, but furnace pressure switches are more likely to fail than many switches. Even then, furnace pressure switches can have a life expectancy of at least 10 years. A furnace pressure switch replacement typically costs around $250.

How do I choose a limit switch?

When selecting the limit switch, the main consideration is the action requirements, installation position and number of contacts, as follows: (1) Select the limit switch type according to the use occasion and control object. (2) Choose the form of protection according to the installation environment.

How do I know if my limit switch is bad?

The most common sign of a malfunctioning limit switch is the continuous operation of your furnace’s blower. Just as the limit switch won’t allow the fan to turn on until the warm air has reached the right temperature, the limit switch also shuts down when the air cools to a certain temperature.

How do I know if my high limit switch is bad?

One of the most common issues that happens when a high limit switch goes bad is that it fails to signal the blower fan to turn off. If your fan keeps running continuously (and you’ve checked that your thermostat is set to AUTO rather than ON), that could be a sign of a bad high limit switch.

Can you reset a limit switch?

The function of your furnace limit switch is to tell the fan when to turn off and on depending on the temperature in the home. However, for your own safety, don’t attempt to reset the switch without first consulting your furnace’s instruction manual.

What is the most expensive part on a furnace?

The heat exchanger is what heats the air that gets circulated around your house, so it’s one of the most important components in your furnace and also one of the most expensive to repair or replace if it gets damaged, cracks, or breaks down.

How do you replace a furnace switch?

Step 1: Remove the Access Cover. Step 2: Locate the Limit Switch. Step 3: Conduct a Voltage Test. Step 4: Turn Off the Power. Step 5: Disconnect the Switch. Step 6: Unscrew and Remove the Switch. Step 7: Install a New Switch. Step 8: Replace the Furnace Cover.

How long do furnaces usually last?

THE AVERAGE FURNACE LIFESPAN A well-maintained furnace can last at least 15 to 20 years, but completing annual maintenance and being diligent with repairs can extend its life even longer.

What are the types of limit switch?

– There are 4 general types of limit switches: whisker, roller, lever, and plunger. – Limit switches are electromechanical devices operated by a physical force applied to it by an object.

Is limit switch a sensor?

Limit switches are a type of sensor that detect presence and absence. Specifically, mechanical limit switches are switches that are mechanically activated, meaning that they have some sort of arm, lever, knob, plunger, etc., which is physically—or mechanically—activated by making contact with another object.

How does a limit switch work on a furnace?

A limit switch is a device that’s located under your furnace’s supply plenum. It reads the temperature of the plenum and waits until it gets appropriately warm. If the temperature inside of the plenum gets too hot, it shuts off the gas supply to your burners to prevent your furnace and heat exchanger from overheating.

Why does my furnace limit switch keep tripping?

A high limit switch will keep tripping due to a dirty flame sensor, short cycling, obstructed airflow, or a defective switch. These lead to overheating within the gas furnace that triggers tripping as a safety measure to prevent fires. Clean and replace dirty and worn-out parts to fix the problem.

How do you manually reset a limit switch?

The contacts open (limit) at a factory set point. Once that limit is reached, a human must manually press the red reset button for the switch to return back to the normally closed state.

How many limit switches are in a furnace?

Identifying the Limit Switch The mounting plate usually contains two or more terminals that receive control wires for the blower fan and the furnace’s gas valve. It’s possible that your furnace will have two or even three limit switches that check temperatures at different parts of the furnace.

Why is my limit switch open?

The limit switch shuts off the burner when the temperature exceeds a preset temperature. When the temperature reduces to normal, the burner will come back on. The most common reason for limits to open is a plugged filter or a dirty blower wheel. On the left are some high temperature limits used in furnaces.