To attain an R-value of R38, a depth or thickness of the blown-in insulation of 15,7″ is needed for fiberglass and 11,98″ for cellulose.
What is the R-value of 12 inches of cellulose?
Typically, the thickness and density of the material determine the R-value. The higher the R-value, the better the material will insulate. The number is presented per inch, so an R-value of 3.1 at 12 inches would provide an overall value of R-38.
What is the R-value of 6 inches of cellulose?
Damp-sprayed loose-fill cellulose insulation has an R-value of up to 3.7 per inch, and it also has superior sealing characteristics. A 6-inch wall cavity that’s insulated with loose-fill cellulose is expected to reach a total R-value of 22.
What is the R-value of cellulose per inch?
The R-value of loose fill cellulose is R-3.2 to 3.8 per inch2. Loose fill fiberglass has an R-value of R-2.2 to 2.7 per inch3. Achieving the desired R-value depends on both the depth of the insulation and its density. Depending on your climate, energy codes require varying R-values for ceiling insulation.
How much insulation do I need for an R38 attic?
The recommended level for most attics is to insulate to R-38 or about 10 to 14 inches, depending on insulation type.
How many inches is R38 blown insulation?
Fiberglass Chart R-Value Thickness Bags / 1000 Sq Ft R49 16.25” 22.6 R44 14.75” 20.1 R38 12.75” 16.8 R30 10.25” 13.0.
What is the R-value of R38 insulation?
Typically insulation is made from materials like; Spray foam, Fiberglass, Cellulose, and Rock Wool. An R-value of R38 is closer to the upper end of R-values and will reduce thermal conductivity by 97 percent related to no insulation.R38 Insulation Thickness For Different Insulation Materials: A Brief Guide. Insulation Material. R38 Thickness Required (Inch) Rock Wool Bat 11.25”.
What is the R-value of 4 inches of insulation?
For areas with 3-4 inches of existing insulation, you will need an R-value of 38-49. For insulating flooring, you will need an R-value of 25-30.
What R-value insulation do I need for garage walls?
Exterior Garage Walls Typically these will be constructed from standard 2-by-4 studs which will define the amount of insulation that you can have installed. You should be targeting an R-Value of R-13 or R-15 in these areas to properly maximize your insulation in this application.
What insulation has the highest R-value per inch?
Vacuum insulated panels have the highest R-value, approximately R-45 (in U.S. units) per inch; aerogel has the next highest R-value (about R-10 to R-30 per inch), followed by polyurethane (PUR) and phenolic foam insulations with R-7 per inch.
What is the R-value of 18 inches of insulation?
Warm Climates (R-30 to R-49): Fiberglass (blown): 14” – 18” Fiberglass (batts): 11” – 14”.
What is the R-value of 10 inches of insulation?
R-value of Materials and Depths Material R-value/in 10″ Fiberglass (batt) 3.1 – 3.4 31.0 – 34.0 Fiberglass blown (attic) 2.2 – 4.3 22.0 – 43.0 Fiberglass blown (wall) 3.7 – 4.3 37.0 – 43.0.
What is the R-value of 3.5 inches of spray foam?
The R-value of open cell spray foam is about 3.5 per inch, although the R-value can be different depending on the product. Open cell spray foam has a low density and is many times applied in interior walls and areas that are hard to reach in a home.
Is R38 attic insulation enough?
Attic Insulation: Houses in a cold climate should have a minimum of R-49 in the attic, which is equivalent to approximately 16″ of fiberglass insulation. Warmer climates only require an R-38 or higher, or about 12″ or more.
How much cellulose do I need?
To determine how much cellulose insulation you need, take the square footage of the space and divide it by either the depth or the desired R-value. Fiberglass blow-in insulation is essentially made up of spun fibers from recycled molten glass.
How thick is our 38 insulation?
10¼ ” thick, R-38C EcoTouch® Thermal Batt insulation prevents moisture damage and help assure long roof life by providing 1″ of ventilation air space between the insulation and roof deck.
Is cellulose insulation better than fiberglass?
At 3.5 per inch of material, the R-value of blown-in cellulose is 23% better per inch than fiberglass batts! According to research done at the Oak Ridge National Lab, fiberglass loses up to 50% of its R-value in very cold conditions; making cellulose a better choice for homes in northern climates.
Can you put too much insulation in your attic?
It’s possible to over-insulate an attic as too much will cause moisture buildup and eventually result in mold. Eventually, adding more insulation leads to diminishing returns in trapping heat as well.
How many square feet is a roll of r38 insulation?
R-38 EcoBatt® Kraft Faced Fiberglass Insulation Batt 24″ x 48″ 64 SF at Menards®.
How do you get a r38 on the ceiling?
An insulation value of R-38 is at the high end and requires a minimum thickness of 12 inches. R-value does not depend on a single layer of insulation. To achieve R-38, you can use two layers of R-19 or three layers of R-13, which give slightly higher thermal resistance.
How thick is r38 insulation batts?
The R-38 high-performance batts are 10˝ to 10-1/4˝ thick as opposed to stan- dard R-38 fiber glass insulation batts of 12˝.
What is the difference between r38 and r49 insulation?
A ceiling with an R-value of 38 lets through only 1/38 of the amount of energy per square foot that passes through that window, or about 2.6% of the energy; a ceiling with an R-value of 49 lets through only 1/49 of the amount of energy per square foot that passes through that window, or about 2.0 % of the energy.