Table of Contents
For a maximum of 30 amps, you’ll need a wire gauge of 10. The most common household item that requires a 30 amp circuit is a central air conditioner.
Can I use a 30 amp breaker on 12-gauge wire?
You should not use a 30-amp circuit breaker on a 12-gauge wire. The circuit breaker installed on a circuit is of a specific size to protect a certain wire gauge. This higher current can damage the thinner wire, melt the insulation, cause short circuits, fire, and even lethal shock.
How far can you run 10-gauge wire for 30 amps?
10-gauge wire can accommodate a 30-amp breaker until you reach 150 feet. At 150 feet or more, you should get 8AWG or 6AWG wire.
How far can you run 8-gauge wire for 30 amps?
10-gauge wire is usually used for short 30 amp runs. If you plan on going over 150 feet, 8-gauge wire or thicker will be needed.
Will a 12 2 wire carry 30 amps?
Can You Use a 12-2 AWG for 30 Amps Circuit. Yes, based on the National Electric Code or NEC, you can use 12-2 AWG cables for THHN or THWN-rated wires. These cables are made for general purposes and can hold up to 194 degrees without taking any damage.
What would you use a 30 amp breaker for?
The 15-amp and 20-amp breakers are used for baseboard heating, the 30-amp breakers are used for water heating, the 40- and 50-amp breakers are used for electric ranges, and the 70-amp breakers are used for air conditioning.
How many amps can you pull on 12 gauge wire?
20 AMPS NM, TW, & UF WIRE (Copper Conductor) SE CABLE (Copper Conductor) 12 AWG – 20 AMPS 6 AWG – 65 AMPS 10 AWG – 30 AMPS 4 AWG – 85 AMPS 8 AWG – 40 AMPS 2 AWG – 115 AMPS 6 AWG – 55 AMPS 1 AWG – 130 AMPS.
What wire do I need for 240v 30 amp?
A 20-amp 240-volt circuit calls for 12-gauge wire; a 30-amp circuit calls for 10-gauge wire; a 40-amp circuit calls for 8-gauge wire; and a 50-amp circuit calls for 6-gauge wire.
What size wire do I need to run 300 feet?
for 300 feet for 100 amp rated service I would use Aluminum direct burial 1/0-1/0-1/0-1/0, the forth can be as low as #4 for the ground (but also in conduit, even if in conduit must still be rated underground wire and required by code also) Also note the size wire the breaker can handle, cannot cut strands to make fit, Jul 28, 2014.
Can I use 8-gauge wire on a 30 amp breaker?
Originally Answered: Can an 8-gauge wire handle 30 amps? Yes, it can. Under the NFPA Article 70 (National Electrcal Code), #8 wire is rated for 50 amps under certain conditions, however it is usually protected at 40 amps.
How much can you run off a 30 amp breaker?
30-amp 240-volt circuit: 30 amps x 240 volts = 7,200 watts.
How long can I run 12 gauge wire?
You can run a 12 gauge wire up to 70 feet on a 15 amp circuit. That number drops to 50 feet if you run 12 gauge wire on a 20 amp circuit.
How many outlets can be on a 30 amp circuit?
20 outlets for 30 amp breaker as a rule of thumb of 1.5 amps per outlet.
Can I use 14 gauge wire on a 30 amp circuit?
If the wire to the 30 Amp breaker is only 14 gauge, you don’t have a breaker, you have a 30 foot long fuse, and it will burn in two before the breaker senses the need to trip. Check out the fan and light if you match the wire size to the breaker size. Yes, it is.
When should I use a single pole 30 amp breaker?
There are several uses for a single-pole breaker. For instance, the main use of this type of breaker is to prevent the overloading and shorting of circuits. Aside from that, 30 amp single-pole breakers are installed for 30A/120V circuits.
How many amps does a TV use?
The average American TV is 50 inches and uses 0.95 amps at 120 volts. That works out to an average TV power consumption of 113 watts. In a given year, the average TV will use 142 kWh and cost a little over 17 dollars (assuming 5 hours of use per day).
How many amps is 1 ought wire good for?
Wire Size and Amp Ratings Wire Size 75°C (167°F) AWG (mm²) Copper 1 (42.4) 130 1/0 (53.5) 150 2/0 (67.4) 175.
How many amps does a dryer use?
Residential electric clothes dryers use between 7.5 amps and 30 amps. However, 30 amps is by far the most common. The National Electrical Code (NEC) standards require that 240V dryers have a dedicated 4-wire circuit (10-3 type NM cable with ground) protected by a 30 amp breaker.
How far can you run 240 volt wire?
As an example, for a 120-volt circuit, you can run up to 50 feet of 14 AWG cable without exceeding 3 percent voltage drop.For 240-volt circuits: 14 AWG 100 feet 10 AWG 128 feet 8 AWG 152 feet 6 AWG 188 feet.
What’s the difference between 10 2 wire and 10 3 wire?
In the case of 10/2 it’s a #10 hot (insulated black), #10 neutral (insulated white) and #10 ground (either bare or insulated green). In the case of 10/3 it’s two #10 hots (insulated black and red), one #10 neutral (insulated white) and one #10 ground (bare or insulated green).
What size wire do I need?
To determine what gauge wire you need, consider the carrying capacity and the amount of current the wire needs to conduct (measured in amperage or amps). Wire gauge is directly related to how many amps you need to run through it. The distance you need the wire to go can also impact the gauge of wire you need.